| Name: | Cold Charging Low Nitrogen Combustion Walking Beam Heating Furnace | Specification: | 35t/h |
|---|---|---|---|
| Heating Steel: | Carbon Structural Steel, High Quality Carbon Structural Steel, Low Alloy Steel, Late Part Of The Excellent Special Steel | Billet Charging Temperature:: | Normal Temperature |
| Billet Heating Temperature:: | 1100~1150℃ | Fuel Type:: | Natural Gas |
| Heat Value: | Q Low = (8500±100) ×4.18KJ/Nm3 | Pressure: | ~8000Pa |
| Highlight: | Walking Beam Heating Furnace,Low Nitrogen Combustion Heating Furnace,Cold Charging Walking Beam Heating Furnace |
||
Cold Charging Low Nitrogen Combustion Walking Beam Heating Furnace
![]()
This project involves the design, manufacture, construction and installation, masonry, coating, commissioning of cold and hot state, personnel training and turnkey project of a walking beam heating furnace with rated output of 35 t/h (cold installation) until normal operation.
It adopts low-nitrogen combustion system, via the two-stroke preheater to preheat combustion air to 350℃, fully recover flue gas heat, save fuel consumption at the same time, reduce the cost of combustion system and spare parts and long-term maintenance, significantly reduce the operating cost; Both theory and practice have proved that fuel consumption can be reduced by 5% when combustion air is increased by 100℃.
Main technical parameter
Technical performance table
|
No. |
Item |
Unit |
Value |
| 1 |
Usage |
Heating before billet rolling |
|
| 2 |
Heating steel grade |
Ordinary carbon steel, low alloy steel, high quality carbon steel, excellent special steel |
|
| 3 |
Standard billet size |
mm | (150×150-380×380)×(4600-6100) |
| 4 |
Single weight of billet |
kg | 767--6420 |
| 5 |
Heating temperature |
℃ | 1030~1150 |
| 6 |
Furnace output |
t/h |
Rated 35 (cold charging) |
| 7 |
Effective bottom strenght |
kg/m2.h |
Rated 465 |
| 8 |
Fuel type |
Natural gas |
|
| 9 |
Low calorific value of fuel |
kJ/Nm3 | 8500±100x4.18 |
| 10 |
Charging temperature |
℃× |
Cold charging: normal temperature |
| 11 |
Unit heat consumption |
kJ/kg billet |
300×4.18(cold charging) |
| 12 |
Gas consumption |
Nm3/h | 1260 |
| 13 |
Air consumption |
Nm3/h | 12600 |
| 14 |
Flue gas amount |
Nm3/h | 13860 |
| 15 |
Heating method and burner |
Low nitrogen burner, side wall of heating section, upper wall of soaking section |
|
| 16 |
Air heat exchanger type |
Metal tubular convection heat exchanger with plug |
|
| 17 |
Air preheating temperature |
℃ | 350 |
| 18 |
Walking beam cooling method |
Water cooling |
|
| 19 |
Consumption of cooling water |
m3/h | 300 |
| 20 |
Walking mechanism transmission mode |
Hydraulic |
|
| 21 |
Walking parameter |
mm |
Step pitch:270 |
|
Lifting: 100+100 |
|||
| 22 |
Walking period |
sec | 35 |
Energy medium requirements
| Flow | Pressure | Heat value | Requirement | |
| Natural gas | 1600Nm3/h (connection point) |
~8000Pa (There is a pressure stabilizer for air supply in the workshop)
|
(8500±100)x4.18kJ/Nm3 | |
| Nitrogen for piping purging |
100 m3/time
|
0.25 MPa | ||
|
Gas for pneumatic mechanism
|
200 m3/h | 0.6 Mpa | no oil, water removal | |
| Gas for instrument | 50 m3/h | 0.6 Mpa |
no oil, water removal, the impurity particle is not larger than 5um
|
|
| Clean circulation water for furnace equipment | 100 m3/h | 0.4 Mpa | ||
|
Turbid circulation water for water seal and slag flushing system
|
30 m3/h | 0.25Mpa | ||
|
Accident water
|
150 m3/h | 0.2Mpa |
Technical performance table
| No. | Item | Unit | Value |
| 1 | Usage | Heating before billet rolling | |
| 2 | Heating steel grade | Ordinary carbon steel, low alloy steel, high quality carbon steel, excellent special steel | |
| 3 | Standard billet size | mm | (150×150-380×380)×(4600-6100) |
| 4 | Single weight of billet | kg | 767--6420 |
| 5 | Heating temperature | ℃ | 1030~1150 |
| 6 | Furnace output | t/h | Rated 35 (cold charging) |
| 7 | Effective bottom strenght | kg/m2.h | Rated 465 |
| 8 | Fuel type | Natural gas | |
| 9 | Low calorific value of fuel | kJ/Nm3 | 8500±100x4.18 |
| 10 | Charging temperature | ℃× | Cold charging: normal temperature |
| 11 | Unit heat consumption | kJ/kg billet | 300×4.18(cold charging) |
| 12 | Gas consumption | Nm3/h | 1260 |
| 13 | Air consumption | Nm3/h | 12600 |
| 14 | Flue gas amount | Nm3/h | 13860 |
| 15 | Heating method and burner | Low nitrogen burner, side wall of heating section, upper wall of soaking section | |
| 16 | Air heat exchanger type | Metal tubular convection heat exchanger with plug | |
| 17 | Air preheating temperature | ℃ | 350 |
| 18 | Walking beam cooling method | Water cooling | |
| 19 | Consumption of cooling water | m3/h | 300 |
| 20 | Walking mechanism transmission mode | Hydraulic | |
| 21 | Walking parameter | mm | Step pitch:270 |
| Lifting: 100+100 | |||
| 22 | Walking period | sec | 35 |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Packaging Details: Wooden case packing or nude packing
Port: Tianjin
Lead Time:
| Quantity(Sets) | 1-1 | >1 |
| Est.Time(Days) | 30 | To be negotiated |
specification